This page is part of the FHIR Specification (v1.0.0: DSTU 2 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
USLab Coded Observation Profile Example: C trachomatis PCR (id = "obs-uslab-example7")
<Observation xmlns="http://hl7.org/fhir"> <id value="obs-uslab-example7"/> <!-- FHIR build is generating the narratives <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <ul> <li>file: obs-uslab-example3.xml</li> <li>id: uslab-example3</li> <li>Name: USLab Observation Example3</li> <li>USLab Coded Observation Profile Example: C trachomatis PCR</li> </ul> </div> </text> --> <!-- extension for specimen reject goes here - not for this use case <extension url="http://hl7.org/fhir/StructureDefinition/uslab-specimenrejectreason"> <valueCodeableConcept> <coding> <system value="http://hl7.org/fhir/v2/0490"/> <code value="EX"/> <display value="Expired"/> </coding> </valueCodeableConcept> </extension> --> <!-- extension for observation kind goes here --> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: obs-uslab-example7</p><p><b>identifier</b>: lab test result ID = 9012 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Chlamydia trachomatis by PCR <span>(Details : {LOINC code '43304-5' = 'Chlamydia trachomatis rRNA [Presence] in Unspecified specimen by Probe and target amplification method', given as 'Chlamydia trachomatis rRNA [Presence] in Unspecified specimen by Probe and target amplification method'}; {urn:oid:2.16.840.1.1 13883.3.72.5.24 code 'CTPCR' = '??', given as 'APTIMA CT'})</span></p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>effective</b>: 05/12/2014</p><p><b>issued</b>: 06/12/2014 3:42:15 PM</p><p><b>performer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>value</b>: Negative for Chlamydia Trachomatis rRNA <span>(Details : {SNOMED CT code '260385009' = '260385009', given as 'Negative'}; {urn:oid:2.16.840.1.1138 83.3.72.5.24 code 'NEG' = '??', given as 'Negative'})</span></p><p><b>interpretation</b>: Normal <span>(Details : {http://hl7.org/fhir/v2/0078 code 'N' = 'Normal)</span></p><p><b>specimen</b>: <a>Urine First Void</a></p></div></text><extension url="http://hl7.org/fhir/StructureDefinition/uslab-observationkind"> <valueCode value="result"/> </extension> <identifier> <use value="official"/> <type> <text value="lab test result ID"/> </type> <system value="http://lis.acmelabs.org/identifiers/labtestresult"/> <value value="9012"/> </identifier> <status value="final"/> <!-- EH : The local and LOINC test codes go here --> <code> <!-- EH: LOINC code goes here --> <coding> <system value="http://loinc.org"/> <code value="43304-5"/> <display value="Chlamydia trachomatis rRNA [Presence] in Unspecified specimen by Probe and target amplification method"/> <!-- EH: LOCAL code goes here --> </coding> <coding> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <code value="CTPCR"/> <display value="APTIMA CT"/> </coding> <text value="Chlamydia trachomatis by PCR"/> </code> <subject> <reference value="Patient/patient-uslab-example1"/> <display value="Todd Lerr"/> </subject> <effectiveDateTime value="2014-12-05"/> <!-- EH: Showing dateTime to ss with TZO although only needed to Day --> <issued value="2014-12-06T15:42:15-08:00"/> <performer> <reference value="Practitioner/pract-uslab-example1"/> <display value="Dr Leonard T Bloodraw Jr"/> </performer> <!-- EH : The local and SNOMED Result codes go here --> <valueCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="260385009"/> <display value="Negative"/> </coding> <coding> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <code value="NEG"/> <display value="Negative"/> </coding> <text value="Negative for Chlamydia Trachomatis rRNA"/> </valueCodeableConcept> <!-- eH dataabsent reason would go here if valueQuantity was empty e.g.: <dataAbsentReason value="error"</dataAbsentReason> --> <interpretation> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="N"/> </coding> </interpretation> <specimen> <reference value="Specimen/spec-uslab-example2"/> <display value="Urine First Void"/> </specimen> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.